AC voltage transducers |
||
MD22-VAC | The transducer is suitable to convert the AC average voltage input to an analog DC voltage/current or a digital RS485 output. Input: (at external power supply) nominal input voltage range (sinusoidal): from 0..5 V to 0..600 V AC Output: (at external power supply) can be ordered with analog OR digital output Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud |
|
MD22-VEF | The transducer is suitable to convert the AC true RMS voltage input to an analog DC voltage/current or a digital RS485 output. Input: (at external power supply) nominal input voltage range (sinusoidal): from 0..5 V to 0..600 V AC Output: (at external power supply) can be ordered with analog OR digital output Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud |
|
AC current transducers |
||
MD22-AAC | The transducer is suitable to convert the AC average current input to an analog DC voltage/current or a digital RS485 output. Input: (at external power supply) nominal input current range (sinusoidal): from 0..0.06 A to 0..5 A AC Output: (at external power supply) can be ordered with analog OR digital output Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud |
|
MD22-AEF | The transducer is suitable to convert the AC true RMS current input to an analog DC voltage/current or a digital RS485 output. Input: (at external power supply) nominal input current range (sinusoidal): from 0..0.06 A to 0..5 A AC Output: (at external power supply) can be ordered with analog OR digital output Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud |
|
AC single phase power transducers |
||
MD22-W | The transducer is suitable to convert the single phase active power input to an analog DC voltage/current or a digital RS485 output. Input: Nominal input voltage range (CF < 1.2): from 0..5 V to 0..600 V AC Nominal input current range (CF < 2): from 0..0.015 A to 0..5 A AC Input power factor range (cos φ): -0.5..+0.5 (C: -60º..L: +60º) Input frequency range: 45...65 Hz Output: (at external power supply) can be ordered with analog OR digital output Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud |
|
MD22-VA | The transducer is suitable to convert the single phase apparent power input to an analog DC voltage/current or a digital RS485 output. Input: Nominal input voltage range (CF < 1.2): from 0..5 V to 0..600 V AC Nominal input current range (CF < 2): from 0..0.025 A to 0..5 A AC Input power factor range (cos φ): -0.5..+0.5 (C: -60º..L: +60º) Input frequency range: 45...65 Hz Output: (at external power supply) can be ordered with analog OR digital output Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud |
|
MD22-VAR | The transducer is suitable to convert the single phase reactive power input to an analog DC voltage/current or a digital RS485 output. Input: Nominal input voltage range (CF < 1.2): from 0..5 V to 0..600 V AC Nominal input current range (CF < 2): from 0..0.025 A to 0..5 A AC Input power factor range (cos φ): -0.5..+0.5 (C: -60º..L: +60º) Input frequency range: 45...65 Hz Output: (at external power supply) can be ordered with analog OR digital output Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud |
|
MD22-PF | The transducer is suitable to convert the single phase power factor input to an analog DC voltage/current or a digital RS485 output. Input: Nominal input voltage range (CF < 1.2): from 0..5 V to 0..600 V AC Nominal input current range (CF < 2): from 0..0.025 A to 0..5 A AC Input power factor range (cos φ): -0.5..+0.5 (C: -60º..L: +60º) Input frequency range: 45...65 Hz Output: (at external power supply) can be ordered with analog OR digital output Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud |
|
AC multiphase power transducers |
||
MD35-W | The transducer is suitable to convert the multiphase active power input to an analog DC voltage/current or a digital RS485 output. Input: Nominal input voltage range (CF < 1.2): from 0..5 V to 0..600 V AC Nominal input current range (CF < 2): from 0..1 A or 0..5 A AC Input power factor range (cos φ): -0.5..+0.5 (C: -60º..L: +60º) Input frequency range: 50 ±1 Hz or 60 ±1 Hz Measuring types: Wb: 3 wires balanced Wb1: 4 wires balanced Wc: 3 wires unbalanced Wd: 4 wires unbalanced Output: (at external power supply) can be ordered with analog OR digital output Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud |
|
MD35-VA | The transducer is suitable to convert the multiphase apparent power input to an analog DC voltage/current or a digital RS485 output. Input: Nominal input voltage range (CF < 1.2): from 0..5 V to 0..600 V AC Nominal input current range (CF < 2): from 0..1 A to 0..5 A AC Input power factor range (cos φ): -0.5..+0.5 (C: -60º..L: +60º) Input frequency range: 50 ±1 Hz or 60 ±1 Hz Measuring types: VAb: 3 wires balanced VAb1: 4 wires balanced VAc: 3 wires unbalanced VAd: 4 wires unbalanced Output: (at external power supply) can be ordered with analog OR digital output Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud |
|
MD35-VAR | The transducer is suitable to convert the multiphase reactive power input to an analog DC voltage/current or a digital RS485 output. Input: Nominal input voltage range (CF < 1.2): from 0..5 V to 0..600 V AC Nominal input current range (CF < 2): from 0..1 A to 0..5 A AC Input power factor range (cos φ): -0.5..+0.5 (C: -60º..L: +60º) Input frequency range: 50 ±1 Hz or 60 ±1 Hz Measuring types: VARb: 3 wires balanced VARb1: 4 wires balanced VARc: 3 wires unbalanced VARd: 4 wires unbalanced Output: (at external power supply) can be ordered with analog OR digital output Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud |
|
Frequency transducer |
||
MD22-F | The transducer is suitable to convert the AC frequency input to an analog DC voltage/current or a digital RS485 output. Input: Nominal input frequency range: 16…400 Hz Nominal input voltage range: 10..600 V AC Output: (at external power supply) can be ordered with analog OR digital output: Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud |
|
DC voltage transducers |
||
MD22-VDC | The transducer is suitable to convert the DC voltage input to an analog DC voltage/current or a digital RS485 output. Input: nominal input voltage range: from 0..±0.06 V to 0..±600 V DC Output: (at external power supply) can be ordered with analog OR digital output Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud |
|
MD22-VI | The transducer is suitable for electrical isolation and conversion the DC voltage input signal. Input: nominal input voltage range: 0..10 V, ±10 V, etc. Can be ordered with analog OR digital output: Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud |
|
DC current transducers |
||
MD22-ADC | The transducer is suitable to convert the DC current input to an analog DC voltage/current or a digital RS485 output. Input: (at external power supply) nominal input current range: from 0..±0.06 A to 0..±5 A DC Can be ordered with analog OR digital output: Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud |
|
MD22-AI | The transducer is suitable for electrical isolation and conversion the DC current input signal. Input: (at external power supply) nominal input current range: 0..20 mA, ±20 mA, 4..20 mA, etc. Can be ordered with analog OR digital output: Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud |
|
DC power transducer |
||
MD22-WDC | The transducer is suitable to convert the DC power input to an analog DC voltage/current or a digital RS485 output. Input: Nominal input voltage range: from 0..±5 V to 0..±600 V DC Nominal input current range: from 0..±0.040 A to 0..±5 A DC Output: (at external power supply) can be ordered with analog OR digital output: Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud |
|
Resistance transducers |
||
MD22-R | The transducer is suitable to convert the resistance input to an analog DC voltage/current or a digital RS485 output. Input: Nominal input resistance range: from 0..100 ohm to 0..100 kohm Can be ordered with analog OR digital output: Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud |
|
MD22-TAP | The transducer is suitable to convert the the ratio of resistors (potentiometer) input to an analog DC voltage/current or a digital RS485 output. Input: Nominal input resistance range (total): from 500 ohm to 100 kohm Can be ordered with analog OR digital output: Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud |
|
Temperature sensor transducers |
||
MD22-TR | The transducer is suitable to convert the thermal resistance input to an analog DC voltage/current or a digital RS485 output. Input: Thermal resistance input range: Pt100 -200 ºC .. +850 ºC Can be ordered with analog OR digital output: Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud |
|
MD22-TC | The transducer is suitable to convert the thermocouple input to an analog DC voltage/current or a digital RS485 output. Input: Thermocouple input range: NiCr-Ni (type K) -190 ºC .. +1300 ºC Fe-Ko (type J) -200 ºC .. +1200 ºC PtRh-Pt (type S) 0 ºC .. +1700 ºC Can be ordered with analog OR digital output: Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud |
|
Pulse counter transducer |
||
MD22-IMP | The transducer is suitable to convert the counting impulse signal to an analog DC voltage/current or a digital RS485 output. The input is controlled by a switch or voltage signal. Input: Pulse counter speed: max. 10 pulse / s Pulse width: min. 1 ms Pulse counter rotation (non volatile): 0..9999 or 0..59999 Can be ordered with analog OR digital output: Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud |
|