AC voltage transducers

  MD22-VAC The transducer is suitable to convert the AC average voltage input to an analog DC voltage/current or a digital RS485 output.

Input: (at external power supply) nominal input voltage range (sinusoidal): from 0..5 V to 0..600 V AC

Output: (at external power supply) can be ordered with analog OR digital output
Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC
Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud
 
  MD22-VEF The transducer is suitable to convert the AC true RMS voltage input to an analog DC voltage/current or a digital RS485 output.

Input: (at external power supply) nominal input voltage range (sinusoidal): from 0..5 V to 0..600 V AC

Output: (at external power supply) can be ordered with analog OR digital output
Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC
Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud
 
 

AC current transducers

  MD22-AAC The transducer is suitable to convert the AC average current input to an analog DC voltage/current or a digital RS485 output.

Input: (at external power supply) nominal input current range (sinusoidal): from 0..0.06 A to 0..5 A AC

Output: (at external power supply) can be ordered with analog OR digital output
Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC
Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud
 
  MD22-AEF The transducer is suitable to convert the AC true RMS current input to an analog DC voltage/current or a digital RS485 output.

Input: (at external power supply) nominal input current range (sinusoidal): from 0..0.06 A to 0..5 A AC

Output: (at external power supply) can be ordered with analog OR digital output
Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC
Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud
 
 

AC single phase power transducers

  MD22-W The transducer is suitable to convert the single phase active power input to an analog DC voltage/current or a digital RS485 output.

Input:
Nominal input voltage range (CF < 1.2): from 0..5 V to 0..600 V AC
Nominal input current range (CF < 2): from 0..0.015 A to 0..5 A AC
Input power factor range (cos φ): -0.5..+0.5 (C: -60º..L: +60º)
Input frequency range: 45...65 Hz

Output: (at external power supply) can be ordered with analog OR digital output
Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC
Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud
 
  MD22-VA The transducer is suitable to convert the single phase apparent power input to an analog DC voltage/current or a digital RS485 output.

Input:
Nominal input voltage range (CF < 1.2): from 0..5 V to 0..600 V AC
Nominal input current range (CF < 2): from 0..0.025 A to 0..5 A AC
Input power factor range (cos φ): -0.5..+0.5 (C: -60º..L: +60º)
Input frequency range: 45...65 Hz

Output: (at external power supply) can be ordered with analog OR digital output
Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC
Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud
 
  MD22-VAR The transducer is suitable to convert the single phase reactive power input to an analog DC voltage/current or a digital RS485 output.

Input:
Nominal input voltage range (CF < 1.2): from 0..5 V to 0..600 V AC
Nominal input current range (CF < 2): from 0..0.025 A to 0..5 A AC
Input power factor range (cos φ): -0.5..+0.5 (C: -60º..L: +60º)
Input frequency range: 45...65 Hz

Output: (at external power supply) can be ordered with analog OR digital output
Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC
Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud
 
  MD22-PF The transducer is suitable to convert the single phase power factor input to an analog DC voltage/current or a digital RS485 output.

Input:
Nominal input voltage range (CF < 1.2): from 0..5 V to 0..600 V AC
Nominal input current range (CF < 2): from 0..0.025 A to 0..5 A AC
Input power factor range (cos φ): -0.5..+0.5 (C: -60º..L: +60º)
Input frequency range: 45...65 Hz

Output: (at external power supply) can be ordered with analog OR digital output
Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC
Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud
 
 

AC multiphase power transducers

  MD35-W The transducer is suitable to convert the multiphase active power input to an analog DC voltage/current or a digital RS485 output.

Input:
Nominal input voltage range (CF < 1.2): from 0..5 V to 0..600 V AC
Nominal input current range (CF < 2): from 0..1 A or 0..5 A AC
Input power factor range (cos φ): -0.5..+0.5 (C: -60º..L: +60º)
Input frequency range: 50 ±1 Hz or 60 ±1 Hz

Measuring types:
Wb: 3 wires balanced
Wb1: 4 wires balanced
Wc: 3 wires unbalanced
Wd: 4 wires unbalanced

Output: (at external power supply) can be ordered with analog OR digital output
Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC
Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud
 
  MD35-VA The transducer is suitable to convert the multiphase apparent power input to an analog DC voltage/current or a digital RS485 output.

Input:
Nominal input voltage range (CF < 1.2): from 0..5 V to 0..600 V AC
Nominal input current range (CF < 2): from 0..1 A to 0..5 A AC
Input power factor range (cos φ): -0.5..+0.5 (C: -60º..L: +60º)
Input frequency range: 50 ±1 Hz or 60 ±1 Hz

Measuring types:
VAb: 3 wires balanced
VAb1: 4 wires balanced
VAc: 3 wires unbalanced
VAd: 4 wires unbalanced

Output: (at external power supply) can be ordered with analog OR digital output
Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC
Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud
 
  MD35-VAR The transducer is suitable to convert the multiphase reactive power input to an analog DC voltage/current or a digital RS485 output.

Input:
Nominal input voltage range (CF < 1.2): from 0..5 V to 0..600 V AC
Nominal input current range (CF < 2): from 0..1 A to 0..5 A AC
Input power factor range (cos φ): -0.5..+0.5 (C: -60º..L: +60º)
Input frequency range: 50 ±1 Hz or 60 ±1 Hz

Measuring types:
VARb: 3 wires balanced
VARb1: 4 wires balanced
VARc: 3 wires unbalanced
VARd: 4 wires unbalanced

Output: (at external power supply) can be ordered with analog OR digital output
Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC
Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud
 
 

Frequency transducer

  MD22-F The transducer is suitable to convert the AC frequency input to an analog DC voltage/current or a digital RS485 output.

Input:
Nominal input frequency range: 16…400 Hz
Nominal input voltage range: 10..600 V AC

Output: (at external power supply) can be ordered with analog OR digital output:
Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC
Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud
 
 

DC voltage transducers

  MD22-VDC The transducer is suitable to convert the DC voltage input to an analog DC voltage/current or a digital RS485 output.

Input: nominal input voltage range: from 0..±0.06 V to 0..±600 V DC

Output: (at external power supply) can be ordered with analog OR digital output
Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC
Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud
 
  MD22-VI The transducer is suitable for electrical isolation and conversion the DC voltage input signal.

Input: nominal input voltage range: 0..10 V, ±10 V, etc.

Can be ordered with analog OR digital output:
Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC
Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud
 
 

DC current transducers

  MD22-ADC The transducer is suitable to convert the DC current input to an analog DC voltage/current or a digital RS485 output.

Input: (at external power supply) nominal input current range: from 0..±0.06 A to 0..±5 A DC

Can be ordered with analog OR digital output:
Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC
Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud
 
  MD22-AI The transducer is suitable for electrical isolation and conversion the DC current input signal.

Input: (at external power supply) nominal input current range: 0..20 mA, ±20 mA, 4..20 mA, etc.

Can be ordered with analog OR digital output:
Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC
Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud
 
 

DC power transducer

  MD22-WDC The transducer is suitable to convert the DC power input to an analog DC voltage/current or a digital RS485 output.

Input:
Nominal input voltage range: from 0..±5 V to 0..±600 V DC
Nominal input current range: from 0..±0.040 A to 0..±5 A DC

Output: (at external power supply) can be ordered with analog OR digital output:
Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC
Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud
 
 

Resistance transducers

  MD22-R The transducer is suitable to convert the resistance input to an analog DC voltage/current or a digital RS485 output.

Input: Nominal input resistance range: from 0..100 ohm to 0..100 kohm

Can be ordered with analog OR digital output:
Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC
Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud
 
  MD22-TAP The transducer is suitable to convert the the ratio of resistors (potentiometer) input to an analog DC voltage/current or a digital RS485 output.

Input: Nominal input resistance range (total): from 500 ohm to 100 kohm

Can be ordered with analog OR digital output:
Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC
Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud
 
 

Temperature sensor transducers

  MD22-TR The transducer is suitable to convert the thermal resistance input to an analog DC voltage/current or a digital RS485 output.

Input: Thermal resistance input range: Pt100 -200 ºC .. +850 ºC

Can be ordered with analog OR digital output:
Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC
Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud
 
  MD22-TC The transducer is suitable to convert the thermocouple input to an analog DC voltage/current or a digital RS485 output.

Input:
Thermocouple input range: NiCr-Ni (type K) -190 ºC .. +1300 ºC
Fe-Ko (type J) -200 ºC .. +1200 ºC
PtRh-Pt (type S) 0 ºC .. +1700 ºC

Can be ordered with analog OR digital output:
Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC
Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud
 
 

Pulse counter transducer

  MD22-IMP The transducer is suitable to convert the counting impulse signal to an analog DC voltage/current or a digital RS485 output. The input is controlled by a switch or voltage signal.

Input:
Pulse counter speed: max. 10 pulse / s
Pulse width: min. 1 ms
Pulse counter rotation (non volatile): 0..9999 or 0..59999

Can be ordered with analog OR digital output:
Analog output range: 0..20 mA, ±20 mA, 4..20 mA, 0..10 V, ±10 V DC
Digital output: RS485, Modbus-RTU, 9.6 / 19.2 kBaud